Nemko offers EMC testing according to military standard MIL-STD 461 D, E and F in our laboratories in Italy and in San Diego.
We provide RF emission measurements from 10Hz to 40GHz and RF immunity testing from 9kHz to 18GHz.
MIL-STD 461 D, E, F test capabilities:
Method |
Description |
---|
CE101 |
Power Leads, 30 Hz to 10 kHz |
CE102 |
Power Leads, 10 kHz to 10 MHz |
CE106 |
Antenna Terminal, 10 kHz to 40 GHz |
CS101 |
Power Leads, 30 Hz to 50 kHz |
CS106 |
Conducted Transient Susceptibility |
CS109 |
Structure Current, 60 Hz to 100 kHz |
CS114 |
Bulk Cable Injection, 10 kHz to 400 MHz Curves 1-5 |
CS115 |
Bulk Cable Injection, Impulse Excitation |
CS116 |
Damped Sinusoidal Transients, Power Leads, 10 kHz to 100 MHz |
RE101 |
Magnetic Field, 30 Hz to 100 kHz |
RE102 |
Electric Field, 10 kHz to 40 GHz |
RS101 |
Magnetic Field, 30 Hz to 100 kHz |
RS103 |
Electric Field, 10 kHz to 18 GHz 10 kHz – 30 MHz: 50 V/m
30 MHz – 100 MHz: 100 V/m
100MHz – 1 GHz: 200 V/m
1 GHz – 4 GHz: 150 V/m
4 GHz – 18 GHz: 50V/m |